BRAND | Kirchner & Tochter |
Product | GSGA-000032 |
Description | Differential Flowmeter |
Internal code | IMP534902 |
Weight | 1 |
Technical specification | (FOLLOW ON ON 10 ON 100 5 - 50 m³/h demineralized water 20°C Total length: 370 mm pmax: 10 bar at 20 °C Housing: EN-GJL-200 Inserts: 1.4571 Lead: 1.4571 Peephole: borosilicate glass Standard flotation: 1.4571 Standard seals: SIL - C 8200 Inner coating: NR (natural rubber) in isoprene quality Anti-corrosion protection: epoxy ester - lacquer paint Oven-dried, traffic blue (RAL 5017) satin gloss Corrosion category: C2 The device is approved according to DGRL for use in Category 2 designed and can also be in Category 1 and Art. 3.3 are used. Customs Tariff No.: 90261081 (such as the previous serial number 05363-08) |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Kirchner & Tochter - GSGA-000032 Differential Flowmeter number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Estonia Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
ROTEX GS 65 ST-H clamping hub 2.6 Ø50H7 Nut - KTR
Measurement range 0.2 - 1.2 m³ / h H2O Scale range: 0.00 to 1.2 m³ / h H2O Tube inside diameter: 21.6 mm Flow direction: bottom to top Overall length: 80 mm Differential pressure: 250 mbar Lens: Brass Accuracy: 5% FS Tariff-No .: 90261081 as previous serial number 12131-001-12
(DDM-DS11-MS1 PN 16 G 3/4-i Measurement range 0.2 - 1.2 m³ / h H2O Scale range: 0.00 to 1.2 m³ / h H2O Tube inside diameter: 21.6 mm Flow direction: bottom to top Overall length: 80 mm Differential pressure: 250 mbar Lens: Brass Accuracy: 5% FS Tariff-No .: 90261081 as previous serial number 12131-001-12; Differential DS11 Seat of the indicator: right Display in flow units incl. adapter plate seals NBR Protection: IP54 Compressive strength: max. 16 bar incl. an adjustable external microswitch, changeover contact Load data: U max. 250 VAC; I max. 5 A; P max. 250 VA U max. 30 VDC; I max. 0.4 A; P max. 10 W; Cable connector, 6-pole with screw)
Range: 2,5 - 15 m³ / h H2O Scale range: 0.00 to 15 m³ / h H2O Tube inside diameter: 53.1 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-007-12
(DDM-DS11-MS1 PN 16 DN 50 Range: 2,5 - 15 m³ / h H2O Scale range: 0.00 to 15 m³ / h H2O Tube inside diameter: 53.1 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-007-12; Differential DS11 Seat of the indicator: right Display in flow units incl. adapter plate seals NBR Protection: IP54 Compressive strength: max. 16 bar incl. an adjustable external microswitch, changeover contact Load data: U max. 250 VAC; I max. 5 A; P max. 250 VA U max. 30 VDC; I max. 0.4 A; P max. 10 W; Cable connector, 6-pole with screw)
Measurement range: 8-48 m³ / h H2O Scale range: 0.00 to 48 m³ / h H2O Tube inside diameter: 82.5 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-010-12
(DDM-DS11-MS1 PN 16 DN 80 Measurement range: 8-48 m³ / h H2O Scale range: 0.00 to 48 m³ / h H2O Tube inside diameter: 82.5 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-010-12; Differential DS11 Seat of the indicator: right Display in flow units incl. adapter plate Seals NBR Protection: IP54 Compressive strength: max. 16 bar incl. an adjustable external microswitch, changeover contact Load data: U max. 250 VAC; I max. 5 A; P max. 250 VA U max. 30 VDC; I max. 0.4 A; P max. 10 W; Cable connector, 6-pole with screw)
Measuring range: 15 - 90 m³ / h H2O Scale range: 0.00 to 90 m³ / h H2O Inside pipe diameter: 107.1 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-012-12
(DDM-DS11-MS1 PN 16 DN 100 Measuring range: 15 - 90 m³ / h H2O Scale range: 0.00 to 90 m³ / h H2O Inside pipe diameter: 107.1 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-012-12; Differential DS11 Seat of the indicator: right Display in flow units incl. adapter plate seals NBR Protection: IP54 Compressive strength: max. 16 bar incl. an adjustable external microswitch, changeover contact Load data: U max. 250 VAC; I max. 5 A; P max. 250 VA U max. 30 VDC; I max. 0.4 A; P max. 10 W; Cable connector, 6-pole with screw)
Flowswitches (Kirchner & Tochter) Monitored range : 6 - 20 l/min H2O Inner diameter : 16,1 mm Installation length : 80 mm Y/ref : 1001302
Flowswitches (Kirchner & Tochter) Monitored range : 2 - 6 l/min H2O Inner diameter : 9,2 mm Installation length : 80 mm Y/ref : 1001301
(RA 87-MSK12 PN 10 G 2 1/4-a 250 - 2500 l/h NaOH 30% 30 °C Größe: 36 Baulänge: 366 mm pmax: 8 bar bei 20° C Plexiglasschutz Hulsenmaterial: 1.4301 Koepfe: 1.4571 Fuhrung: 1.4571 Messglas: Borosilicatglas Standardschwebekörper: PTFE mit Magnetkern Standarddichtungen: FPM The DGRL for the Einsatz in Category 2 ausgelegt and kann auch Category 1 and Art. 3.3 eingesetzt werden. The DGRL for the Einsatz in Category 2 ausgelegt and kann auch Category 1 and Art. 3.3 eingesetzt werden. Zoll-Tarif-No.: 90261081)